• Product NO:SA-120-AA
    Input Voltage:90-264VAC
    Output Current:3600mA
    Output Power:120W
    Size:196*68*38mm
DETAILS

 

 ■Features

·International full-range input voltage
·Protection: shortcircuit/overload/overvoltage/overheat
·Natural air cooled
·100% full load aged
·Idle power < 1.5 W
·All capacitors are 105℃ long-life electrolytic
·Capacity of surge of 300VAC: 5 seconds
·Working temperature up to 70℃
·Passes 5G vibration test
·High efficiency, long life & high reliability
·2-year warranty
·Waterproof grade: IP67

 

Specifications

Product No. SA-120-AA
Output DC voltage 27-36V
Current 3600mA
Vltg range 20-36V
Power 100W
Ripple & noise 150mV P-P
Current accuracy ±10mA
Linear adj ±5%
Load adj ±5%
Start & rise 1000mS,3mS\230VAC   1000mS\115VAC(full loaded)
Input Voltage 90-264VAC
Frequency 47-63Hz
Efficiency 85%
AC current 0.15A\230V  0.216A\115V
Surge Cold start:230V 20A
Current leak 2mA\230VAC
Protection Output shortcircuit Mode:Hiccup with automatic recovery when output shortcircuit is over
Overheat Overheat protection starts when transistor contact temperature is over 130
Mode: output voltage shut-off with automatic recovery when temperature return to normal
Environment Working temp. -20~ +60
Working Hmdty 5-95%RH
Storage Temp. -40~ +80℃、
Vibration proof 10500Hz,5G 10min/round,X, Y, Z axes 60 sec. Each
Safety rules and electro-magnetic tolerance (Note 6) Regulations GB195110.1-2004/IEC61347-1:2003  CE(EMC+LVD)
Voltage I/P-O/P:1.5KVAC   IP-GND:1.5KVAC
Insulation I/P-O/P:I/P-FG,O/P-FG:100MOhms/500VDC/25/70%RH   
EM irradiation EN 55015:2006;EN61000-3-2:1995+A2:2005
EM disburbance proof EN 61000-3-2:2006;
Size 196*68*38MM
Packing 18pcs/carton  0.91kG/pc
Notes: 1. Unless otherwise stated, all data are taken in the condition of 230VAC input, rated load, and 25.
2. Ripple and noise measurement: with a 12” double ripple cord, parallel connected with 0.1-μF and 47-μF capacitors, the data are measured in 20MHz brandwidth.
3. Accuracy: including preset error, linear adjustment and load adjustment rate.
4. Linear adjustment rate: from low voltage to high voltage, measured under rated load
5. Load adjustment rate: from 0% to 100% of rated load
6. Power supply is regarded as a part of the system, which needs to be confirmed of electro-magnetic relation with terminal instruments 


Copyright 2016-2017    Shenzhen Xingzhiyou Technology Co.ltd